Adil Khan 11 months ago
AdiKhanOfficial #FYP Ideas

Design of three phase relay circuit electrical trainer having fault inserting and troubleshooting to provide industrial exposure

This Trainer (Design of three Phase Relay Circuit Electrical Trainer Having Faulty Inserting & Troubleshooting To provide industrial Exposure) provides a course on the operation and trouble shooting for electrical control circuits. It has a unique control training capabilities with a f

Project Title

Design of three phase relay circuit electrical trainer having fault inserting and troubleshooting to provide industrial exposure

Project Area of Specialization

Electrical/Electronic Engineering

Project Summary

This Trainer (Design of three Phase Relay Circuit Electrical Trainer Having Faulty Inserting & Troubleshooting To provide industrial Exposure) provides a course on the operation and trouble shooting for electrical control circuits. It has a unique control training capabilities with a fault insertion system which is useful as a teaching aid in fault-finding or troubleshooting the electrical installation. Connection between the components are made by using stack-cable 4 mm test leads, which plugs into 4 mm color-coded heavy-duty captive-head binding post. Fault simulator switches installed at special closed box which placed at back of trainer.

The unit consists of various real industrial components that are common to electrical installation and control circuits. These components are mounted onto a training display board and their electrical components are bought out 4 mm terminals. During the student exercises connection are made by test leads, which gives the student through the experiment and provides the necessary theoretical background to allow student successfully to complete the educational objectives. The topic include: varieties of contactor, thermal overload, typical of connections and wiring diagrams motor control for star connection, motor control for delta connections and wiring diagrams, motor control for star delta connection, fault finding and trouble shooting.

Project Objectives

  1. Familiarization of circuit protection devices..
  2. Install circuit of direct on line starter (DOL) circuit
  3. Explain work principle and trouble shooting of regulated cam switch.
  4. Install circuit of “start-stop three phase induction motor circuit completed by control safety devices.
  5. Explain work principle and trouble shooting of emergency switch.
  6. Installation the thermal overload in power wiring and control wiring.
  7. Testing and setting of thermal overload.
  8. Explain the thermal overload work principle and trouble shooting.
  9. Install check and differentiate power lamp indicators and control lamp indicators
  10. Do troubleshooting of lamp indicators.
  11. Explain work principle and trouble shooting of push button.
  12. Install and operate the forward and reverse of three phase induction motor circuit by using   magnetic contactors.
  13. Explain the magnetic contactor work principle and trouble shooting.
  14. Explain the effect of mechanical interlocking failure of magnetic contactors.
  15. Explain the function, work principle of time delay relay and magnetic contactors.
  16. Install circuit of three phase induction motor by using time delay relay and magnetic contactors.
  17. Analyze and trouble shooting of starting failure by using time delay relay and magnetic contactors.
  18. Install circuit of automatic star delta motor starting by using magnetic contactors and time delay relay.
  19. Analyze and trouble shooting of automatic star delta motor starting failure.
  20. Familiarization of circuit protection devices..
  21. Install circuit of direct on line starter (DOL) circuit
  22. Explain work principle and trouble shooting of regulated cam switch.
  23. Install circuit of “start-stop three phase induction motor circuit completed by control safety devices.
  24. Explain work principle and trouble shooting of emergency switch.
  25. Installation the thermal overload in power wiring and control wiring.
  26. Testing and setting of thermal overload.
  27. Explain the thermal overload work principle and trouble shooting.
  28. Install check and differentiate power lamp indicators and control lamp indicators
  29. Do troubleshooting of lamp indicators.
  30. Explain work principle and trouble shooting of push button.
  31. Install and operate the forward and reverse of three phase induction motor circuit by using   magnetic contactors.
  32. Explain the magnetic contactor work principle and trouble shooting.
  33. Explain the effect of mechanical interlocking failure of magnetic contactors.
  34. Explain the function, work principle of time delay relay and magnetic contactors.
  35. Install circuit of three phase induction motor by using time delay relay and magnetic contactors.
  36. Analyze and trouble shooting of starting failure by using time delay relay and magnetic contactors.
  37. Install circuit of automatic star delta motor starting by using magnetic contactors and time delay relay.
  38. Analyze and trouble shooting of automatic star delta motor starting failure.

Project Implementation Method

This  study utilized  the developmental  type  of  research. An electrical Fault trainer comprised of A 36 inches by 42 inchs 18 guage metal body which served as  a trainer board placed on a metal frame having 2 legs with a length of  15  inches which  served as  a stand. It was equipped with a low current circuit breaker to facilitate safe operations and eliminate damages to all the devices.  It was  capable  of  handling  a  residential-like,  commercial-like and  industrial-like  electrical  wiring / installation, troubleshooting,  and  commissioning.

Benefits of the Project

This training set provides students with the opportunity to practice a method of error on the basic malfunctions in Electrical circuits. This set aims to inform students about the most common faults can generate 30 basic faults, such as;

?Fault in emergency Red Lamp.

?Push button ON-2 (NO).

?Push button ON-1 (NO).

?Time Delay Relay ( A2 Coil).

?Magnatic Contactor-1 (L1).

?Magnatic Contactor-1 ( Auxilary NO 13/14).

?Time Delay Relay (Comon).

?Emergency Push Button. (NC).

?Magnatic Contactor-3 (A1 Coil).

?Thermal Over Load (97).

?Thermal Over Load (95).

Technical Details of Final Deliverable

This training set provides students with the opportunity to practice a method of error on the basic malfunctions in Electrical circuits. This set aims to inform students about the most common faults can generate 30 basic faultsThe trainer has some main components as follows:

1.Main Miniature Circuit Breaker (MCB)   Three phase 32A.

2.Regulated Cam Switch 1,0,2..

3.Control Miniature Circuit Breaker (MCB)   Single Phase 6A.

4.Push Button for Emergency Stop.

5.Power Indicator Lamp for LI/R, L2/Y, L3/B

6.Magnetic Contactor Three Main Pole, Auxiliary Contact 2NO, 2NC Coil 220VAC.

7.Control Lamp Indicator for Run, Overload, Emergency.

8.Time Delay Relay (ON Delay Timer)

9.Thermal Overload Relay 1-1.6A

10.Push Button Switches NO/NC 12. Fault Simulator Switches

11.Set of Test Leads

12.Power Cable

13. Fault Simulator Switches

Final Deliverable of the Project

Hardware System

Core Industry

Education

Other Industries

Manufacturing

Core Technology

Others

Other Technologies

Sustainable Development Goals

Quality Education

Required Resources

Item Name Type No. of Units Per Unit Cost (in Rs) Total (in Rs)
3-pole Miniature Circuit breaker Equipment150005000
1-pole miniature Circuit Breaker Equipment1800800
3-Phase Magnetic Contactor Equipment3480014400
3-Phase selector Switch Equipment125002500
Emergency Switch Equipment110001000
Thermal overload relay Equipment135003500
Time Delay Relay Equipment120002000
Push Button Equipment1400400
Structure frame Equipment11200012000
Front Vinyl Sheet Equipment140004000
Miscellanea Transport Miscellaneous 3300900
cutting disk Miscellaneous 5150750
drill bits Miscellaneous 25001000
hole saw Miscellaneous 110001000
Indication Lamp Equipment6100600
Heavy Male/Female Connectors Equipment15010015000
3/0.029 Cable Equipment128002800
2 mm Flexible Cable Equipment135003500
Screw Miscellaneous 2200400
Nuts & bolts Miscellaneous 3527945
Nuts & bolts 1/2 Miscellaneous 3030900
Total in (Rs) 73395
If you need this project, please contact me on contact@adikhanofficial.com
Smart Mirror Based Information System for Department of Electronics En...

A smart mirror can act as a personal assistant and notice board for learning activities. S...

1675638330.png
Adil Khan
11 months ago
Design and Implementation of Six Axis Drilling Robot

In this project each axis will be control by servo/stepper motors. The robot is programmed...

1675638330.png
Adil Khan
11 months ago
Battery less and Wireless Conveyor Belt System

The main objective we are striving for is to provide maximum facilities for Pack...

1675638330.png
Adil Khan
11 months ago
Autonomous Robotic Arm Based on Computer Vision

We are doing Bachelors in Electronics Engineering from Sukkur IBA University. Our final ye...

1675638330.png
Adil Khan
11 months ago
Pharmaceutical Sales Management System

With the advancement in the field of technology, people have now become more familiar, how...

1675638330.png
Adil Khan
11 months ago