Measurement and Extraction of Non-invasive Fetal ECG from Maternal ECG Signal

Heart defects are among the most common birth defects and the leading cause of birth defect-related deaths. Every year, about one out of 125 babies are born with some form of congenital heart defects. The defect may be so slight that the baby appears healthy for many years after birth, or so severe

2025-06-28 16:34:05 - Adil Khan

Project Title

Measurement and Extraction of Non-invasive Fetal ECG from Maternal ECG Signal

Project Area of Specialization Biomedical EngineeringProject Summary

Heart defects are among the most common birth defects and the leading cause of birth defect-related deaths. Every year, about one out of 125 babies are born with some form of congenital heart defects. The defect may be so slight that the baby appears healthy for many years after birth, or so severe that its life is in immediate danger. Congenital heart defects originate in the early stages of pregnancy when the heart is forming and they can affect any of the parts or functions of the heart. Like for adults, it should be possible to visualize the electrical activity of a fetal heart.

The abdominal ECG signal contains fetal ECG signal, the maternal ECG component, and noise. To estimate the fetal ECG signal from the abdominal ECG signal, removal of the noise and the maternal ECG component presented in it is necessary.

Measurement and Extraction of Non-invasive Fetal ECG from Maternal ECG Signal _1582926475.png

Currently, there are two ways to obtain a fetal ECG. One is the invasive scalp electrode method, which can directly measure the pure fetal ECG signal. However, it can only detect fetal ECG signals during birth, and because it is invasive it may cause harm to the mother and the fetus. Another method is the non-invasive abdominal electrode method. Signals from the abdominal body surface are collected by placing an electrode patch in the abdomen of the mother, which allows for long-term monitoring during pregnancy. However, the signals from the maternal abdominal surface are very complex, containing not only maternal ECG and weak fetal ECG signals, but also the mother’s respiratory noise, frequency interference, and other signals. In particular, the magnitude of the maternal ECG detected in the abdomen is about 2–10 times that of the fetal ECG, which makes the extraction of the fetal ECG difficult. Therefore, it is necessary to develop a non-invasive method that can extract the fetal ECG effectively.

For this purpose, we designed an ECG fabricated circuit using all the compliances and standards. Using the circuit we acquired ECG data from patients (mothers) and separated the fetal ECG signal from maternal ECG and noise using different algorithms. 

At present, fetal ECG extraction algorithms mainly include adaptive filtering, wavelet analysis, matched filtering, blind source separation (BSS), independent component analysis (ICA), neural network, and singular value decomposition (SVD).

Challenges of Fetal Signal Extraction

Measurement and Extraction of Non-invasive Fetal ECG from Maternal ECG Signal _1582926476.pngAs the above graph depicts, the frequency range of the fetal ECG component covers all the maternal biopotential signals and has a very low amplitude, so it is very critical for us to extract it.

Project Objectives
  1. Design and implementation/Fabrication of ECG circuit: ECG circuit designed according to the compliance and standards 
  2. Collecting ECG signal from mother: ECG signal collected from mother using three-channel ECG hardware and BIOPAC
  3. Ensuring patient safety: Shielding isolators are used so that current from electrodes should be kept at a safe level
  4. Acquiring/Acquisition ECG signal in a PC: Data acquisition is done using DAQ card and Labview
  5. Pre-processing of ECG Signal: The raw signal is preprocessed and noise is removed using a Bandpass filter
  6. Separating FECG from maternal ECG: fetal ECG is separated using different types of algorithms
Project Implementation Method Methodology:

Measurement and Extraction of Non-invasive Fetal ECG from Maternal ECG Signal _1582926477.png

In each hospital or clinic following steps will be executed:

Benefits of the Project

During pregnancy, monitoring the fetus’ heart condition in order to test their well-being and diagnose possible diseases is of paramount importance. An early diagnosis before delivery using noninvasive techniques increases the effectiveness of the appropriate treatment. Fetal electrocardiogram (FECG) shows the muscular function and electrical activity of the fetal heart. It represents the characteristics such as dynamic behaviors, waveform and heart rate of the fetus. These characteristics help to determine fetal development, the existence of fetal distress, fetal life, intrauterine hypoxia, fetal maturity or congenital heart disease. So these above characteristics can be used for the conduction of appropriate treatment. Currently, fetal electrocardiography (FECG) seems to offer the most promising method to detect fetal hypoxia. Fetal hypoxia is a pathological state that occurs when the fetus is deprived of an adequate supply of oxygen. It can be caused by a number of reasons such as umbilical cord prolapses, cord occlusion or cord thrombosis, placental infarction and others. The non-invasive fetal ECG extraction technique can theoretically be performed at almost any point in the pregnancy. 

Detection of fetal disease in time can allow us to cure the congenital heart disease before further complications. 

Technical Details of Final Deliverable Hardware Design

The product of our project is an ECG hardware that is able to collect ECG data. The ECG signal than obtained will contain maternal ECG. fetal ECG and noise. 

The ECG signal is collected by hardware comprising of:

For shielding and isolation:

The ECG hardware circuit is encased in an acrylic box.

Measurement and Extraction of Non-invasive Fetal ECG from Maternal ECG Signal _1582926477.png

Software Implementation Final Deliverable of the Project HW/SW integrated systemCore Industry MedicalOther Industries Health Core Technology OthersOther TechnologiesSustainable Development Goals Good Health and Well-Being for PeopleRequired Resources
Item Name Type No. of Units Per Unit Cost (in Rs) Total (in Rs)
Total in (Rs) 75000
AD620 Equipment53251625
Capacitor Equipment55351925
resistor pack Equipment1250250
circuit breaker Equipment36802040
fuse Equipment550250
battery charger Equipment132003200
rechargeable cells Equipment87005600
rechargeable batteries Equipment45902360
shipping Miscellaneous 1250250
ECG Socket Adapters Equipment36001800
cell holder Equipment3100300
aux socket Equipment640240
aux port Equipment640240
breadboard Equipment4180720
PCB board Equipment53001500
LM 35 Equipment5150750
IN5817 Equipment81080
connecting wires Equipment2520500
potentiometer Equipment520100
LM 358 Equipment1520300
LF33 Equipment1050500
LM741 Equipment1030300
coloured printing Miscellaneous 4020800
photostates Miscellaneous 405200
stationery Miscellaneous 1200200
seperating sheets Miscellaneous 1320260
travels uber Miscellaneous 153905390
travels careem Miscellaneous 124002400
electrodes Equipment510005000
leads Equipment6185011100
acrylic box Equipment130003000
soldering iron Equipment1950950
pcb fabrication Equipment27501500
cell charger Equipment122202220
electrode gel Equipment55002500
glue gun Equipment110001000
glue gun sticks Miscellaneous 1050500
aluminion base Equipment130003000
wire cutter Equipment215003000
Digital multimeter Equipment1850850
extension wire Equipment213502700
casing cost Equipment218003600