IOT based distribution panel is the type of panel which used for to distributing the input source to different output load while operating with smart techniques. For this purpose we will be using an android app to perform the various task like controlling and operating function and
IOT based controlling of distributing panel to Maintain Power Factor in Industry
IOT based distribution panel is the type of panel which used for to distributing the input source to different output load while operating with smart techniques. For this purpose we will be using an android app to perform the various task like controlling and operating function and also showing the current, voltage, power factor to user on mobile screen. It is also showing the above factors on the LCD for the user. It’s improving the load power factor. Raspberry Pi Programming it can interface analogue quantities i.e. current and voltage Power factor improvement and load management.
To design an autonomous distribution Panel Switch on/off appliances smartly, Utility bill can be managed in bounded limits, Make monitoring of all appliances in industries or commercial
The Raspberry Pi 3 Model B+
ESP- 8266
Current Transformer (CT)
| Class of Accuracy | 0.5 |
| Rated Burden | 5.00 VA |
| Power Frequency Withstand Voltage | 3KV |
| Highest System Voltage | 433 V |
| Nominal System Voltage | 400 V |
| Frequency | 50 Hz |
| Supply System | 3 Ph. Solidly grounded Neutral System |
3-Phase inductive motor with the following data
| 1 | Rated power | 2 hp |
| 2 | Rated frequency | 60 Hz |
| 3 | Rated Input Voltage | 220 V |
| 4 | Rated Speed | 1164 RPM |
| 5 | Number of poles | 6 |
| 6 | Stator Resistance | 0.294 ohm |
| 7 | Stator leakage Inductance | 1.39 mH |
| 8 | Rotor Resistance | 0.156 ohm |
| 9 | Rotor Leakage inductance | 0.74 mH |
| 10 | Magnetizing inductance | 41.0mH |
| 11 | Moment of Inertia / Motor & Load | 0.8 kgm^2 |
| 12 | 1 hp = 746 watt |
Capacitor Bank
Power Factor Control
The PFC relay/equipment shall have a range suitable for proper selection of switching In/Out of the Sub-banks to maintain the Target Power Factor via the PLC. The relay PF setting range shall be.
0.8 CAPACITIVE – UNITY –0.8 INDUCTIVE
The relay shall have as a minimum a digital display of PF, Target PF, Operation Time Delay, voltage and current.
Class of Accuracy
Rated Burden
Power Frequency Withstand Voltage
Highest System Voltage
Nominal System Voltage
Frequency
Supply System
1
2
3
4
5
6
7
8
9
10
11
12
| 1 | Rated power | 2 hp |
| 2 | Rated frequency | 60 Hz |
| 3 | Rated Input Voltage | 220 V |
| 4 | Rated Speed | 1164 RPM |
| 5 | Number of poles | 6 |
| 6 | Stator Resistance | 0.294 ohm |
| 7 | Stator leakage Inductance | 1.39 mH |
| 8 | Rotor Resistance | 0.156 ohm |
| 9 | Rotor Leakage inductance | 0.74 mH |
| 10 | Magnetizing inductance | 41.0mH |
| 11 | Moment of Inertia / Motor & Load | 0.8 kgm^2 |
| 12 | 1 hp = 746 watt |
Vehicles, specially cars, play a vital role in our everyday life. They transport people fr...
Skin disease has a lower impact on mortality compared to others but instead, it has a grea...
We are designing ?Automatic Temperature and Mask Scanning Disinfection System for Covid-19...
As our project is to take the one of the process from the different processes working in t...
Innovation is the charm of 4th Industrial Revolution. ICT Organizations all over the world...