Adil Khan 1 year ago
AdiKhanOfficial #FYP Ideas

Electrical Impededance tomography

Electrical impedance tomography (EIT) is a noninvasive type of medical imaging in which the electrical conductivity, permittivity, and impedance of a part of the body (lik

Project Title

Electrical Impededance tomography

Project Area of Specialization

Biomedical Engineering

Project Summary

Electrical impedance tomography (EIT) is a noninvasive type of medical imaging in which the electrical conductivity, permittivity, and impedance of a part of the body (like lungs in our case) is inferred from surface electrode measurements and used to form a tomographic image of that part. 

Project Objectives

Development of a system that is radiation-free, non-invasive, and can produce images of lungs with a high temporary resolution for bedside ventilation.

Project Implementation Method

The current of 1 mA at 20 kHz is applied between two specific electrodes and the potential will be measured from the remaining electrodes. Through that, we are going to find the impedance and an impedance matrix will be formed and then an image reconstruction algorithm will reconstruct an image. This is shown below 

figure1

Benefits of the Project

Electrical impedance tomography is a very promising technique for the noninvasive, radiation-free monitoring of lung function. It is widely applicable and safe for the patient, allowing real-time continuous monitoring of mechanical properties of the lungs over extended periods of time.

Technical Details of Final Deliverable

An imaging system will be developed that can produce low cost, non-invasive, radiation-free, and high temporal resolution, but with a low spatial resolution image that can be used bedside for ventilation purposes.

Final Deliverable of the Project

HW/SW integrated system

Core Industry

Others

Other Industries

Medical

Core Technology

Others

Other Technologies

Sustainable Development Goals

Industry, Innovation and Infrastructure

Required Resources

Item Name Type No. of Units Per Unit Cost (in Rs) Total (in Rs)
AD9850 Miscellaneous 120002000
Arduino Mega Miscellaneous 114001400
Raspberry Pi 4 Equipment11480014800
TFT touch screen 7 inches Select Type177007700
5x5 m^2 Cu electrodes Equipment3230960
Total in (Rs) 26860
If you need this project, please contact me on contact@adikhanofficial.com
0
181
Industrial PLC trainer for AC servo motor related application

In this Project of PLC trainer students learns how to make program for controlling of...

1675638330.png
Adil Khan
1 year ago
Smart Under Frequency Load Shedding System

The title of our project is, Smart Under-Frequency Load Shedding System for Industry Plant...

1675638330.png
Adil Khan
1 year ago
Smart wheelchair for elderly and disabled people

Elderly & disabled people prone to be dependet on caretaker. When a person becomes phy...

1675638330.png
Adil Khan
1 year ago
A TRAINING SYSTEM FOR CARDIOPULMONARY RESUSCITATION AND BLOOD PRESSURE...

The project is intended for training and testing the capability of medical staff while per...

1675638330.png
Adil Khan
1 year ago
Simulation and experimental based fundamental investigation on the sur...

The titanium alloys are widely used in the biomedical, aerospace and automotive industries...

1675638330.png
Adil Khan
1 year ago