This study aims to calculate the performance of the ND of wet cooling tower (NDWCT) using first law (energy) and second law (exergy) of thermodynamics. Moreover, it determines the economic feasibility and sustainability of the ND Wet Cooling Tower. An appropriate mathematical model will be 
Experimental Investigation of ND Wet Cooling Tower
This study aims to calculate the performance of the ND of wet cooling tower (NDWCT) using first law (energy) and second law (exergy) of thermodynamics. Moreover, it determines the economic feasibility and sustainability of the ND Wet Cooling Tower. An appropriate mathematical model will be developed and simulated in software like Engineering Equation Solver, Solidworks & MATLAB, to calculate water savings, performance and payback period of additional investment. The simulation results would have a good agreement with the experimental outcomes. The installation of modified heat Air-Air to Air-Liquid exchanger will improve the performance of WCT by up to 11% because the consumption of water to air ratio increases. Moreover, the exergy destruction in the NDWCT is 1.23 MW lower than the conventional WCT. Additionally, the heat exchanger costs k$30.7 to save an annual fuel cost of k$72 which could be recovered within a payback period of 0.37 years. Lastly, the environmental assessment proves that the NDWCT relinquishes the particulate matter emission by 0.042 g/s.
Our project is an industrial based project, that will be beneficial and economical for industry. it may take up to expected 6 months to make it ready to work. it will be delivered within 6th month to the department of Mechanical Engineering Mehran University of Engineering and technology Shaheed Z.A Bhutto campus Khairpur Mir’s
| Item Name | Type | No. of Units | Per Unit Cost (in Rs) | Total (in Rs) |
|---|---|---|---|---|
| Copper Pipe | Equipment | 100 | 210 | 21000 |
| Nylon Pipe | Miscellaneous | 50 | 60 | 3000 |
| Water Heater | Equipment | 2 | 300 | 600 |
| Hygrometer | Equipment | 2 | 500 | 1000 |
| Thermometer | Equipment | 2 | 800 | 1600 |
| Pressure gauges | Equipment | 2 | 900 | 1800 |
| Submerged pump | Equipment | 1 | 500 | 500 |
| pH meter | Equipment | 1 | 900 | 900 |
| Copper wire | Equipment | 20 | 40 | 800 |
| Battery | Equipment | 1 | 12000 | 12000 |
| Solar panel | Equipment | 1 | 12000 | 12000 |
| blower fan | Equipment | 1 | 5000 | 5000 |
| Centrifugal pump | Equipment | 1 | 12000 | 12000 |
| oil paint | Miscellaneous | 4 | 700 | 2800 |
| seal clips | Miscellaneous | 200 | 15 | 3000 |
| Screw driver | Miscellaneous | 1 | 500 | 500 |
| Total in (Rs) | 78500 |
This system allows a user to control a fire fighter robot Equipped with water tank and gun...
In this project we want to develop a system comprising of sensors and microprocessor for d...
Load demands nowadays is increasing sharply and to meet those demand, we have to improve t...
This project actually work for one place at a time just like a restaurant so, by usin...
The objective of this project is to develop an application that can cater to an individual...