The faults in overhead distribution lines are easy to detect, as the faults can be seen clearly. For example, when a tree falls on the line any pole is damaged and the conductor impaired to the ground. The location of faults is usually done by circuit detaching or som
DESIGN OF THREE PHASE DISTRIBUTION LINE PROTECTION SCEHEME
The faults in overhead distribution lines are easy to detect, as the faults can be seen clearly. For example, when a tree falls on the line any pole is damaged and the conductor impaired to the ground.
The location of faults is usually done by circuit detaching or some time circuit is under power there are different techniques to detect faults such as Murray loop/ Blavier test using current and voltage measurement at the end of cables. Also by tracer method. This work on inspection on the length of cable. The terminal method locates the general fault in the prescribed area along a long cable. In a general wiring system, a time-domain reflectometer used for the location of the fault. At low voltage insulation fault is not detected easily, the high energy applies using a “thumper” test set high voltage pulse provide the cable. Discharge at the fault produces sound. The fault is located by listening to this sound this test damage at the cable site practically it is re insulated due to fault location. In a distribution system with high resistance, the system operation remains to continues after a feeder develops a fault to ground. The faulted but feeder can be connected with a ring-type current transformer for the collection of phase lines for easy detection of ground-fault current.
In this project, we are going to model the distribution system and design its protection scheme (differential protection, overcurrent protection, overvoltage protection, fault location detection, and ground faults) using a microcontroller and IoT.
We intend the following qualities in it
The following methodology will use to model and design the protection scheme of the distribution line.
This project makes the distribution system more reliable and smart, and it can be easily implementable in all DESCOs.
This project-based on three-phase distribution lines. In this project, we will create different types of faults to check the reliability and response time of the protection system. The instrument transformers sense the voltage and current and fed it to the controller. The differential protection scheme also used to protect the transformer and distribution lines. The controller will generate the control signal for switching of different relays depending upon the situation. The proposed methodology makes the distribution system more reliable and smart.
| Item Name | Type | No. of Units | Per Unit Cost (in Rs) | Total (in Rs) |
|---|---|---|---|---|
| Instrument Transformers | Equipment | 3 | 500 | 1500 |
| Controller | Equipment | 3 | 2500 | 7500 |
| Power supply | Equipment | 2 | 5000 | 10000 |
| Relays | Equipment | 20 | 150 | 3000 |
| Power resistor | Equipment | 20 | 100 | 2000 |
| LCD | Equipment | 3 | 750 | 2250 |
| MOSFET | Equipment | 30 | 70 | 2100 |
| Cables | Equipment | 1 | 2000 | 2000 |
| Wifi Module | Equipment | 2 | 750 | 1500 |
| Electrical load | Equipment | 10 | 150 | 1500 |
| Capacitors | Equipment | 30 | 40 | 1200 |
| Miscellaneous | Miscellaneous | 1 | 10000 | 10000 |
| Transformer | Equipment | 6 | 1000 | 6000 |
| Switches and Electric board | Equipment | 4 | 250 | 1000 |
| 3D printing | Equipment | 1 | 4000 | 4000 |
| Total in (Rs) | 55550 |
style="display:inline;">I affirm that all information submitted through this FYP applicati...
Phased arrays are based on the principle that a consistent phase shift(time delay) in the...
Our project is called an environment monitoring system. This project consists of a drone o...
Business Management and Analysis Project consist of two parts, first part is managem...
Our project?s aim is to design and program a robot to autonomously move in an unstructure...