Design and fabrication of Rheumatoid arthritis Patients mobility aided device.

There are many people who suffer from arthritis disease, because of that they can not sit and stand easily. In Pakistan, equipment, which can aid such kind of patients, are not widely available. Our aim is to design and fabricate a device which will help these people. For its fabrication, our focus

2025-06-28 16:26:22 - Adil Khan

Project Title

Design and fabrication of Rheumatoid arthritis Patients mobility aided device.

Project Area of Specialization Biomedical EngineeringProject Summary

There are many people who suffer from arthritis disease, because of that they can not sit and stand easily. In Pakistan, equipment, which can aid such kind of patients, are not widely available. Our aim is to design and fabricate a device which will help these people. For its fabrication, our focus is to select that kind of material which is light weight and have high strength. After doing stress analysis on different materials, we have decided to choose Aluminum to complete the fabrication process. Our device consists of different parts, which include calf plate, thigh plate, back support, and remote-controlled electric actuators.

Project Objectives

Following are the main objectives in which this device can be Beneficial:

Project Implementation Method

Person will wear this device. When the person wants to Stand up, he will push the button, device will stand him up slowly without help of other person. And vice versa.

Benefits of the Project

Following are the benefits :

Technical Details of Final Deliverable

In this device we use two remote controlled electric linear actuators, each has 12V motor and they can operate at minimum current of 2 Ampere.There Power Capacity are 20W or Maximum 30W. The Stroke of actuator is 150 mm and each actuator can lift the weight upto 40 Kg. The actuators are connected with Calf and Thigh plate. Stroke of actuators can move the thigh plate at angle of 90° to 180°.

Final Deliverable of the Project Hardware SystemCore Industry MedicalOther Industries Health Core Technology RoboticsOther Technologies Wearables and ImplantablesSustainable Development Goals Good Health and Well-Being for People, Decent Work and Economic Growth, Industry, Innovation and InfrastructureRequired Resources
Item Name Type No. of Units Per Unit Cost (in Rs) Total (in Rs)
Total in (Rs) 80000
Remote-controlled electric linear actuators Equipment21500030000
Material Equipment14000040000
Machining cost Miscellaneous 11000010000