Three phase induction motors are mostly used in industry for various operations. Here the implementation of monitoring system for 3-phase induction motor based on programable logic controller(PLC) & SCADA technology is described. Also the implementation of a hardware and software for speed contr
Controlling and Monitoring of three phase induction motor with fault deduction through SCADA
Three phase induction motors are mostly used in industry for various operations. Here the implementation of monitoring system for 3-phase induction motor based on programable logic controller(PLC) & SCADA technology is described. Also the implementation of a hardware and software for speed control, direction control, parameter monitoring on SCADA screen is provided. VFD can also use to control the motor rotation direction and rotation speed of the three phase induction motor. All the required control and motor performance monitoring data will be taken to a personal computer by SCADA software via PLC for further analysis.
1. It can be used specially for workplace employee to reduce hard work.
2. It can be useful for the records of machine progress and production.
3. Fault detection will be find easily.
4. It will be efficient to need the data and operate accordingly by your own choice.
This method is very easy for implementation of this project, SCADA is basicaly like a supervisor that how to start motor and also the progress of machine, production etc.. PLC is commanding and VFD controls the speed , also in the end SCADA will monitor everything like motors speed, RPM, rotation etc..
1. Helpful for the employer to be updated with labours work , also the progress of machine.
2. By using of IP address employer or engineer can access the system through their pc or any available device.
3. Time saving and efficient monitoring system.
4. Useful for continous monitoring.
1. Use of SCADA helps us to make database as well as in communication between employee/employer and the production machine.
2. Data security.
3. Efficient system.
4. Its operation function is easily to be accessible
| Item Name | Type | No. of Units | Per Unit Cost (in Rs) | Total (in Rs) |
|---|---|---|---|---|
| PLC | Equipment | 1 | 10000 | 10000 |
| VFD | Equipment | 1 | 10000 | 10000 |
| SCADA | Equipment | 1 | 35000 | 35000 |
| CT | Equipment | 1 | 1500 | 1500 |
| Contactors, pannel etc | Miscellaneous | 1 | 10000 | 10000 |
| Total in (Rs) | 66500 |
Up until now if any aspiring student who wants to get admission in SZABIST had any query r...
PROJECT SUMMARY: Clean and healthy environment is very important for our society. However,...
The project focuses on the devlopement of active lower limb orthosis that will help people...
This project is based on sensing the hazardous conditions inside the mine as well as sensi...
A stair-climbing wheelchair, sometimes known as a wheelchair stair climber, is a mobi...